Page view 42
DT  System  Technical Guide 40
What's Slave Address
2wire DT system is capable of connecting up to 4 Monitors in one apartment, which means they will have the same
User Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below:
• 1. All the Monitors of same apartment must be programmed with the same User Code on the DIP switches.
• 2. There is only one master Monitor in the one aparment, and the Slave Address of the master Monitor is set to 0.
Each Slave Monitor should be set from 1~3.
• By default, Monitor’s Slave Address is preset to 0(master Monitor).
• When Door Station calls, only the master Monitor will turn on the screen, the slave Monitor will only ring.
Slave Address
1
Slave Address
0
Master Monitor Slave Monitor 1 Slave Monitor 2 Slave Monitor 3
Slave Address
2
Slave Address
3
Please note, when called by Door Station, all Monitors will ring, however, only the Monitor which Sub User Code was
programmed to 0 will turn on the screen.
Programming Slave User Code is by means of Monitor Menu, in the Main> Setup> Advance Set page(a password
will be required before enter the setting, the password is:
2008
), operate as below:
H o m e I n t e l l ig e n t Syst e m
Other settings...
Informations...
Slave Addr Set -- 0
Guard Unit Set -- 0
Date and Time set...
Exit
• The Slave Addr Set item is for the master and slave
user code setting, default is set to 0 for master user
code. It can be change to 1, 2 or 3.
• The Guard Unit Set item is for Guard Unit Monitor
setting, the default it set to 0, if set to 1, this Monitor is
become a Guard Unit Monitor.
Page view 42